Trauma Monthly

Published by: Kowsar

Femoral Pseudoaneurysms Requiring Surgical Treatment

Hannu Savolainen 1 , * , Iris Baumgartner 2 , Juerg Schmidli 2 , George Heller 2 , Do-Dai Do 2 and Torsten Willenberg 2
Authors Information
1 Academic Department of Surgery, Queen Elizabeth Hospital, Bridgetown, Barbados
2 Swiss Cardiovascular Center, University Hospital, 3010 Berne, Switzerland
Article information
  • Trauma Monthly: January 15, 2012, 16 (4); 194-197
  • Published Online: January 15, 2012
  • Article Type: Research Article
  • Received: October 22, 2011
  • Revised: October 30, 2011
  • Accepted: November 25, 2011
  • DOI: 10.5812/kowsar.22517464.3186

To Cite: Savolainen H, Baumgartner I, Schmidli J, Heller G, Do D, et al. Femoral Pseudoaneurysms Requiring Surgical Treatment, Trauma Mon. 2012 ; 16(4):194-197. doi: 10.5812/kowsar.22517464.3186.

Abstract
Copyright © 2012, Trauma Monthly. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
1. Background
2. Objectives
3. Patients and Methods
4. Results
5. Discussion
Acknowledgements
Footnotes
References
  • 1. Kronzon I. Diagnosis and treatment of iatrogenic femoral artery pseudoaneurysm: a review. J Am Soc Echocardiogr. 1997; 10(3): 236-45
  • 2. Norwood MG, Lloyd GM, Moore S, Patel N, Panditi S, Sayers RD. The changing face of femoral artery false aneurysms. Eur J Vasc Endovasc Surg. 2004; 27(4): 385-8[PubMed]
  • 3. Nehler MR, Taylor LM, Porter JM. Iatrogenic vascular trauma. Semin Vasc Surg. 1998; 11(4): 283-93[DOI]
  • 4. Koreny M, Riedmuller E, Nikfardjam M, Siostrzonek P, Mullner M. Arterial puncture closing devices compared with standard manual compression after cardiac catheterization: systematic review and meta-analysis. JAMA. 2004; 291(3): 350-7[DOI][PubMed]
  • 5. Kadner A, Schmidli J, Schwegler I, Dick F, Schonhoff F, Carrel T, et al. Complications associated with the arterial puncture closure device--Angio-Seal. Vasc Endovascular Surg. 2008; 42(3): 225-7[PubMed]
  • 6. Manuel-Rimbau E, Lozano P, Gomez A, Bethencourt A, Gomez FT. [Iatrogenic vascular lesions after cardiac catheterization]. Rev Esp Cardiol. 1998; 51(9): 750-5[DOI][PubMed]
  • 7. MacDonald LA, Meyers S, Bennett CL, Fintel D, Grosshans N, Syegco R, et al. Post-cardiac catheterization access site complications and low-molecular -weight heparin following cardiac catheterization. J Invasive Cardiol. 2003; 15(2): 60-2[DOI][PubMed]
  • 8. Sackett WR, Taylor SM, Coffey CB, Viers KD, Langan EM, Cull DL, et al. Ultrasound-guided thrombin injection of iatrogenic femoral pseudoaneurysms: a prospective analysis. Am Surg. 2000; 66(10): 937-40[PubMed]
  • 9. Lewis DR, Bullbulia RA, Murphy P, Jones AJ, Smith FC, Baird RN, et al. Vascular surgical intervention for complications of cardiovascular radiology: 13 years’ experience in a single centre. Ann R Coll Surg Engl. 1999; 81(1): 23-6[PubMed]
  • 10. Magosaki N, Hosoda S, Kawagishi N, Yamaguchi T, Sakatani H, Haze K, et al. [Efficacy of hemostatic puncture closing device for hemostasis and early ambulation after coronary angiography and angioplasty: results of a multicenter trial]. J Cardiol. 1999; 34(3): 131-8[PubMed]
  • 11. Brachmann J, Ansah M, Kosinski EJ, Schuler GC. Improved clinical effectiveness with a collagen vascular hemostasis device for shortened immobilization time following diagnostic angiography and percutaneous transluminal coronary angioplasty. Am J Cardiol. 1998; 81(12): 1502-5[PubMed]
  • 12. Assessment of the safety and efficacy of the DUETT vascular hemostasis device: final results of the safe and effective vascular hemostasis (SEAL) trial. Am Heart J. 2002; 143(4): 612-9[DOI][PubMed]
  • 13. Görge G, Kunz T. Management of Complex Two-chamber False Aneurysms by Thrombin Injections in Patients Under Clopidogrel, Aspirin or Both. Int J Angiol. 2003; 12(2): 119-21[DOI]
  • 14. Chatterjee T, Do DD, Mahler F, Meier B. Pseudoaneurysm of femoral artery after catheterisation: treatment by a mechanical compression device guided by colour Doppler ultrasound. Heart. 1998; 79(5): 502-4[DOI]
  • 15. Lazarides MK, Tsoupanos SS, Georgopoulos SE, Chronopoulos AV, Arvanitis DP, Doundoulakis NJ, et al. Incidence and patterns of iatrogenic arterial injuries. A decade’s experience. J Cardiovasc Surg (Torino). 1998; 39(3): 281-5[PubMed]
  • 16. Sultan S, Nicholls S, Madhavan P, Colgan MP, Moore D, Shanik G. Ultrasound guided human thrombin injection. A new modality in the management of femoral artery pseudo-aneurysms. Eur J Vasc Endovasc Surg. 2001; 22(6): 542-5[DOI][PubMed]
Creative Commons License Except where otherwise noted, this work is licensed under Creative Commons Attribution Non Commercial 4.0 International License .

Search Relations:

Author(s):

Article(s):

Create Citiation Alert
via Google Reader

Readers' Comments